“When we drained one of our turbine oil filter housings, inductively coupled plasma (ICP) elemental analysis showed phosphorus levels at about 1,600 parts per million (ppm), which is abnormal. The acid number was approximately 0.29. Do you have any insight as to what could be causing the high phosphorus levels?”